BETA-LUGB Vortex Flowmeter Without Temperature & Pressure Compensation
BETA-LUGB Vortex flowmeter work on the principle of generated vortex and relation between vortex and flow by theory of Karman and Strouhal, which specialize in measurement of steam, gas and liquid of lower viscosity.




| Pipe diameter | DN10-DN300 |
| Accuracy | 1.0% 1.5% |
| Range Ratio | 1:8 |
| Ingress protection | IP65 |
Wafer connection | DN15-DN300(priority PN2.5MPa) |
| Flange connection | Flange connection: DN15-DN50(priority PN2.5MPa) DN250-DN300(priority PN1.0MPa) DN15-DN50(priority PN2.5MPa) |
Accuracy | Gas without compensation: DN15-DN25--1.5%, DN32-DN200--1.0%, DN250-DN300--1.5% |
| Range Ratio | Gas density:1.2kg/m3, Range ratio: 8:1 |
| Medium Temperature | -20°C ~ +150°C、-20°C ~ +260°C、-20°C ~ +300°C |
| Power Supply | 24VDC±5% Li battery(3.6VDC) |
| Output signal | 4-20mA Frequency RS485 communication (Modbus RTU) |
| Ingress protection | IP65 |
| Body Materials | Display |
| Display | 128*64 dot matrix LCD |
A fluid flowing with a certain velocity and passing a fixed obstruction generates vortices. The generation of vortices is known as Karman’s Vortices.The frequency of vortex shedding is a direct linear function of fluid velocity and frequency depends upon the shape and face width of bluff body.
Since the width of obstruction and inner diameter of the pipe will be more or less constant, the frequency is given by the expression:
f=StV/d
In the formula:
f – Karman vortex frequency generated at one side of bluff body (Hz)
St – strouhal number (non-dimensional number)
V – average speed of fluid (m/s)
d – width of bluff body (m)
เรื่องน่าสนใจอื่น ๆ
-
BETA-TMF450
BETA-TMF450 Thermal Gas Mass Flowmeter (BETA-TMF450) Item No.: 15.1 Thermal mass.....
-
District ultrasonic heat meter
District ultrasonic heat meter District Ultrasonic Heat (Cooling) Meter (BETA-HN.....
-
District ultrasonic water meter
District ultrasonic Water meter (Bulk water meters) (BETA-W7)Item No.: 26.4BETA-.....
-
BETA-2000H Series Hand-held
Hand-held ultrasonic flow meter(BETA-2000H)Item No.:21BETA-2000H Ultrasonic Flow.....
-
BETA-2000F2 Series lntegral
lntegral ultrasonic flow meter (BETA-2000F2)Item No.:26BETA-2000F2 Ultrasonic Fl.....
-
T3 Ultrasonic water meter
Ultrasonic water meter (BETA-T3-1)Item No.:26.1BETA-T3-1 dual channel ultrasonic.....
-
BETA-LUGB Vortex flowmeter with temperature & pressure compensation
BETA-LUGB Vortex Flowmeter With Temperature & Pressure CompnsationBETA-LUGB .....
-
BETA-LDG Remote type electromagnetic flowmeter
BETA-LDG Remote Type Electromagnetic Lfowmeter Electromagnetic flowmeter is.....